C-30HDNI (PRECISION) PUMP — MAINTENANCE (PUMP)

Detent Hole (3) Installation

1. After the bearing assembly has been is installed , remove the

three “dog type” allen head set screws (B) to allow detents to
be drilled. See Figure 26 below.

The detent holes will prevent the
bushing from sliding away from the
bearing spacer when the pump is
under load.

2. Use a 9/32” drill to “detent” half (minimum 1/8” deep). Then

“chase” the threads with a 3/8-16 bottom tap and blow out the
chips after drilling, to be certain that the “dog type” allen set
screws bottom in the detents to prevent the taper bushing from
sliding laterally.

3. If this procedure is not followed closely the heavy loading

of the bearing during pumping operation causes the
Timken

cone bearings to create lateral forces which will

move the taper bushing and allow the Timken

cone

bearings to separate from the race and subsequently fail.

Figure 26. Detent Holes

4. Drill (detent) the shaft under the allen set screws “B” to prevent

the bushing from the sliding away from the bearing spacer
when the pump is under a load.

NOTE

Position the ‘O’ ring on the O.D. of the
bearing spacer during assembly to
assure proper bearing adjustment.

NOTE