PAGE 24 — MAYCO C-30HDNI (PRECISION) PUMP — OPERATION AND PARTS MANUAL — REV. #7 (04/03/12)

C-30HDNI (PRECISION) PUMP — CONTROL BOX COMPONENTS

Figure 8. Pump Control Box Components

Figure 8 illustrates the location of the major components for the
C-30HDNI Control Box. The function of each component is
described below:

1. Throttle Control Switch – This is a variable speed type

control. Holding the control switch to the

left

increases the

engine speed. To place the engine at IDLE speed, hold the
control switch to the

right

and let the engine run for 3-5

minutes.

2. Trouble Indicator LED– This is a diagnostic feature on the

C-30HDNI to assist the operator with identifying problems
that occur with the fuel injection system (See Table 7).

3. Oil Pressure Indicator Lamp – In the event of low oil in the

engine crankcase or low oil pressure, the oil "

Oil

Pressure

Lamp

" indicator will be lit. STOP the engine immediately if

this lamp is lit.

NEVER

run the engine when this lamp is on.

4. Battery Charge Indicator Lamp – Indicates if the electrical

system is charging properly. If the "

Battery Charge

Indicator

Lamp

" is lit, this is an indication that the charging system is

malfunctioning. STOP the engine and remedy the electrical
charging problem.

5. Water Temperature Lamp – In the event of high engine

water temperature (220 degrees Fahrenheit), this lamp will
be lit. STOP the engine immediately if this lamp comes on.

NEVER

run the engine when this lamp is on.

6. Ignition Switch – Insert the ignition key here to start the

engine. Turn the key clockwise to the ON position, then
continue turning clockwise to the START position and
release. To stop the engine turn the key fully counter-
clockwise to the

STOP position.

7. Remote Control Input Connector – Insert the remote

control input cable into this connector.

8. Pumping Control Switch – This 3-position switch controls

the pumping of the pump. The

left most

position is for use

with the remote control unit, the

center

position is for off

(prevents pumping), and the

right most

position is for

normal pump operation.

9. Hourmeter– Display's the number of hours the pump has

been in use.