beautypg.com

Components (generator) – Multiquip GAC-9.7HZ User Manual

Page 18

background image

page 18 — gaC9.7HZ 60 HZ geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #2 (03/31/10)

15.

engine Oil drain plug – Remove this drain plug

when draining of the oil from the engine crankcase

is required. Fill with recommeded type oil as listed in

Table 4

16.

engine Oil dipstick – Remove oil dipstick to check

engine oil level.

17.

Fuel drain plug – Remove plug to drain fuel.

18.

Fuel gauge – This gauge is located on top of the fuel

tank. Read this gauge to determine when fuel is low.

19.

spark plug – Provides spark to the ignition system.

Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch)

Clean spark plug once a week.

20.

Recoil starter (pull rope) – Manual-starting method.

Pull the starter grip until resistance is felt, then pull

briskly and smoothly.

21.

Fuel Tank/Cap – Remove fuel cap to add fresh

unleaded fuel. Fuel tank capacity is 10 gallons (38

liters).

22.

Battery – This generator is equipped with a 12 VDC

battery. Replace with only recommended type battery.

23.

Choke lever – Used for starting the engine. Close

the choke lever when starting a cold engine or in

cold weather conditions. The choke enriches the fuel

mixture. Open the choke lever if starting a warm engine

or in warm weather conditions

24.

muffler/Heat shield – Used to reduce noise and

emissions.

NeveR touch this heat shield when the

generator/welder is in use. Always allow time for engine

to cool before servicing.

25.

Oil Filter – Replace oil filter as referenced in

maintenance section of this manual.

26.

engine Oil Filler Hole – Remove cap when the adding

of engine oil is required. See Table 4 for recommended

type engine oil.

27.

air Cleaner – Prevents dirt and other debris from

entering the fuel system. Release retaining clips on top

of air filter cover to gain access to filter element.

NeveR run the engine without an air cleaner.

NOTICE

This

HONda engine is equipped with a low oil

shutdown capability. A built in sensor will automatically

turn off the engine should the oil level fall below a safe

operating condition. Make sure the generator is placed

on level ground. Placing the generator on level ground

will ensure that the low oil sensor will function properly.

COMpOnents (generatOr)

Figure 4. Generator Components (continued)