background image

PAGE 18 — QP2TH TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #5 (01/29/14)

OPERATION

STARTING THE ENGINE

1. Place the engine fuel valve lever (See Figure 7) to the

ON position.

Figure 7. Engine Fuel Valve Lever (ON Position)

2. Move the throttle lever (See Figure 8) away from the

slow position, about 1/3 of the way toward the fast

position.

Figure 8. Throttle Lever (1/3 Start Position

3. Place the choke lever (See Figure 9) in the

CLOSED

position if starting a cold engine.

Figure 9. Engine Choke Lever (Closed)

CAUTION

DO NOT attempt to start the engine unless the pump

has previously been primed with water. Severe pump

damage will occur if pump has not been primed.

4. Place the

choke lever (See Figure 10) in the OPEN

position if starting a warm engine or the temperature

is warm.

Figure 10. Engine Choke Lever (Open)

5. Place the engine

ON/OFF switch (See Figure 11) in

the

ON position.

Figure 11. Engine ON/OFF Switch (ON Position)

6. Grasp the starter grip (See Figure 12) and slowly pull

it out. The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 12. Starter Grip

7. If the engine has started and the choke lever was

moved to the

CLOSED position to start the engine,

gradually move the choke lever to the

OPEN position

(Figure 13) as the engine warms up. If the engine has

not started repeat steps 1 through 6.