4. Visually inspect to determine if hydraulic oil level is
low. If oil level is low add Shell Tellus 46 hydraulic oil or
equivalent through the hand pump oil filler port.
5. When adding hydraulic oil, only fill to the specified oil
level as marked on the front of the hydraulic oil tank
(Figure 7). DO NOT overfill.
Checking the Air Cleaner
1. Loosen the wing nut and remove the air cleaner cover
as shown in Figure 8.
2. Remove the paper filter element and inspect it for signs
of wear or dirt. If paper filter element is dirty, clean or
replace element.
INSPECTION
CAUTION — Oil Leaks
DO NOT overfill hydraulic oil tank. This could cause oil
leaks and sluggish operation. Clean cap and
surrounding area before opening to prevent dirt from
entering oil tank.
Figure 9. Refueling
DANGER — Fuel Hazard
Adding fuel to the tank should be done
only when the engine is stopped and has
had an opportunity to cool down. In the
event of a fuel spill, DO NOT attempt to
start the engine until the fuel residue has
been completely wiped up and the area surrounding
the engine is dry.
AIR CLEANER
COVER
WING
NUT
PAPER
FILTER
ELEMENT
FOAM
FILTER
ELEMENT
GASKET
Figure 8. Air Cleaner Element
Figure 7. Oil Tank (Front View)
Figure 6. Hydraulic Oil Filler Plug Removal
Checking The Fuel
1. Remove the fuel cap located on top of fuel tank.
2. Visually inspect to see if fuel level is low. If fuel is low,
replenish with unleaded gasoline. (Figure 9).
3. When refueling, be sure to use a strainer for filtration.
DO NOT top-off fuel. Wipe up any spilled fuel.