beautypg.com

Pro-panel ii – Metal Sales Pro-Panel II Manual User Manual

Page 6

background image

PPP-6

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

PRO-PANEL II

®

s

eCTion

P

roPerTies

and

l

oad

T

ables

Anti-Siphon Groove

C

36" Coverage

3

1

/

8

"

2

3

/

4

"

9"

5

/

8

"

Optional

Profile

ALLOWABLE UNIFORM LOADS PSF

(3 or More Equal Spans)

2' 2.5' 3' 3.5' 4' 5'

2' 2.5' 3' 3.5'

4' 5'

SECTION PROPERTIES

Bottom in Compression

Width

(in.)

Yield

KSI

36"

80

36"

80

29

Ga.

26

Sxx

In

3

/ft

Ixx

In

4

/ft

Weight

PSF

0.71
0.87

Top in Compression

Sxx

In

3

/ft

Ixx

In

4

/ft

0.0067 0.0134 0.0047 0.0133

90 58 41 27 18 9 90 59 41 27 18 9

0.0090 0.0181 0.0063 0.0170

115 75 52 35 23 12 122 79 55 35 23 12

Inward

Load

Outward

Load

1. Theoretical section properties have been calculated per AISI 2001 "Specification for the Design of Cold-Formed Steel Structural Members.”

Ixx and Sxx are effective section properties for deflection and bending.

2. Allowable load is calculated in accordance with AISI 2001 specifications considering bending, shear, combined bending and shear and

deflection. Allowable load considers the worst case of 3 or 4 equal span conditions. Allowable load does not address web crippling or

fastener/support connection and panel weight is not considered.

3. Deflection consideration is limited by a maximum deflection ratio of L/180 of span.

4. Allowable loads do not include a 1/3 stress increase in uplift.

5. Diaphragm 306 plf average Ultimate Shear Strength using the above fastening pattern on 2x supports located 2' on center per ASTM E455-04

Slope

Substructure

Coverage

Length

Fasteners

Availability

GENERAL INFORMATION

ATTACHMENT DETAIL

The minimum recommended slope for Pro-Panel II

®

roof

panel is 3:12.

Pro-Panel II

®

is designed to be utilized over open structural

framing, or a solid substrate. To avoid panel distortion, use

a properly aligned and uniform substructure.

Pro-Panel II

®

panels are available in a

5

/

8

" rib height with a

coverage width of 36".

Minimum factory cut length is 5'-0". Maximum

recommended panel length is 45'-0". Longer panels

require additional consideration in packaging, shipping, and

erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for

choosing the proper fastener for specific applications.

Quantity and type of fastener must meet necessary loading

and code requirements.

NOTE: All panels are subject to surface distortion due to

improperly applied fasteners. Overdriven fasteners will

cause stress and induce oil canning across the face of the

panel at or near the point of attachment.

Finishes: Acrylic Coated Galvalume

®

or MS Colorfast45

®

Gauges: 26 ga and 29 ga standard

FASTENING PATTERN

Anti-Siphon Groove

1

/

4

"-14 x

7

/

8

" Stitch Screw (1'-0" o.c.)

#9-15 Woodscrew

1

/

4

"-14 x

7

/

8

" Stitch Screw

#9-15 Woodscrew

Optional

Profile