PPP-2

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11

800.406.7387 (Corporate Office) • www.metalsales.us.com

PRO-PANEL II

®

P

anel

o

verview

PANEL PROFILE

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any Pro-Panel II roofing panel is 3:12.

Pro-Panel II is designed to be utilized over open structural framing, but can easily be used with a solid substrate.

The recommended substrate is

5

/

8

" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use

a properly aligned and uniform substructure.

Pro-Panel II panels are available in a 36" width with a

5

/

8

" rib height.

Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-0".

Longer panels require additional consideration in packaging, shipping, and erection. Please consult your Metal

Sales branch for recommendations (see PGI-2 and PGI-3 for locations).

Pro-Panel II panels are available in 26 gauge.

Commercial and Industrial panel.

Direct Fasten (Exposed)

The fastener selection guide should be consulted for choosing proper fasteners for specific applications.

Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).

Steel grade 50 per ASTM A-792

Steel grade 80 per ASTM A-792 or ASTM A-653

*

Acrylic Coated Galvalume

®

(ACG) / ASTM A-792 - AZ55

Prepainted Galvalume / ASTM A-792 - AZ50

MS Colorfast45

®

**

Fluorocarbon (PVDF)

*

Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection.

**

Meets both Kynar 500 and Hylar 5000 specifications.

Anti-Siphon Groove

C

36" Coverage

3

1

/

8

"

2

3

/

4

"

9"

5

/

8

"

2"

11

/

16

"

PERFORMANCE TEST

UL 2218, UL 790, Miami-Dade County Approved, Texas Department of Insurance