SERVICING
Repair and replacement work should only be performed by a qualified service technician.
Always shut off the gas supply and make sure heater is cool before beginning any service
operation. Check for gas leaks after servicing.
REPAIR PARTS
A parts list with exploded view follows. Always include correct name, part number, and model
number of the heater when ordering service parts. Please contact your local dealer or distributor
when ordering . If one is not available, you may contact.
New Buck Corporation
8000 Highway 226 South
Spruce Pine, NC 28777
BURNER ORIFICES SIZES:
“For natural gas when equipped with No. 46 drill size orifice.”
“For propane when equipped with No. 1.50mm drill size orifice.”
NOTE: “This appliance equipped only for altitudes 0-2000 feet (0-610m).”