beautypg.com

2 description, 3 function, 4 technical data – Memmert Central water supply User Manual

Page 6: 5 intended use and improper use

background image

6

Construction, description and function

1.2 Description

The steam generator in MEMMERT appliances with humidity control is supplied with

demineralised water from tanks that must be regularly refilled with commercially avail-

able demineralised water. Using demineralised water is imperative, as otherwise pumps

and pipes could become calcified.
With a central water supply, up to three MEMMERT appliances with humidity control

can be supplied with demineralised water. The tanks, and therefore refilling, are then no

longer necessary.

1.3

Function

Via the supply tube (Fig. 1, No. 4), tap water is fed through the filter cartridges (10) and

this way demineralised. The demineralised water is channelled, float controlled, to a wa-

ter supply tank (8) connected (6) with three tube connectors to the front of the appliance

(1). Up to three MEMMERT appliances with humidity control can be connected here.
The conductivity of the demineralised water – and thus the correct function of the filter

cartridges – is measured continuously by a monitoring unit (5), supplied via the connec-

tion on the front of the appliance (2) with 12 V direct current by the included plug-in

power supply unit. If the conductivity exceeds a certain value, the LED at the front will

flash (3, see also page 10) and a warning signal will sound. Then, the filter cartridges

must be replaced (see page 10).

1.4

Technical data

Height (mm)

735

Width (mm)

355

Depth (mm)

255

Weight [kg]

15 (with empty water supply tank)

Power supply

12 V DC via power supply unit 230/110 V AC

1.5 Intended use and improper use

The central water supply must only be used to supply MEMMERT appliances with humid-

ity control with demineralised water. Any other use is improper, and may result in dam-

age. In particular,

connecting other appliances to the central water supply is not permissible

filling the central water tank with fluids other than drinking water with a pressure of

maximum 2.5 bar and a maximum temperature of 40 °C

operation with other filter inserts than those provided by the manufacturer

attaching and fitting parts not approved by the manufacturer