MAMAC Systems TE-213 User Manual
Rohs, Technical information, Temperature sensor

8189 Century Boulevard • Minneapolis, MN 55317-8002 • USA
800-843-5116 • 952-556-4900 • Fax 952-556-4997
[email protected] • www.mamacsys.com
Model TE-211Z/213
Technical Information
TI.211Z/213-05
TEMPERATURE SENSOR
RoHS
ORDERING INFORMATION:
ORDERING INFORMATION:
Installation
Probe
Length
Probe
Material
Well
Fitting
Supply
Voltage
Signal
Output
Range
A Space
1 24 VDC
E 4-20 mA
2 wire
E 4-20 mA
2 wire
E 4-20 mA
2 wire
E 4-20 mA
2 wire
E 4-20 mA
2 wire
E 4-20 mA
2 wire
1 24 VDC
1 24 VDC
1 24 VDC
1 24 VDC
1 24 VDC
2 Stainless
Steel
2 Stainless
Steel
2 Stainless
Steel
A Brass
1/4” NPT
B Brass
1/2” NPT
1
50 to 85°F
2 40 to 140°F
4 0 to 100°F
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
TE-211Z
(4-20 mA)
Model
B Duct
C Immersion
D Duct Averaging
E Remote Probe
Strap On
F Outside Air
(Weatherproof)
A 4 inches/
100mm
B 6 inches/
150mm
C 8 inches/
200mm
D 12 inches/
300mm
A 4 inches/
100mm
B 6 inches/
150mm
C 8 inches/
200mm
7 Custom
E 2 inches/
50mm
1 Aluminum
F 6 feet/
1.8 m
G 12 feet/
3.6 m
H 24 feet/
7.2 m
A Space
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
2 Stainless
Steel
2 Stainless
Steel
2 Stainless
Steel
A Brass
1/4” NPT
B Brass
1/2” NPT
1 50 to 85°F
2 40 to 140°F
4 0 to 100°F
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
2 40 to 140°F
3 -30 to 130°F
4 0 to 100°F
5 100 to 250°F
6 0 to 250°F
7 Custom
TE-213
(VDC)
B Duct
C Immersion
D Duct Averaging
E Remote Probe
Strap On
F Outside Air
(Weatherproof)
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
1 24 VDC
2 24 VAC
B 0 - 5 VDC
C 0 - 10 VDC
7 Custom
A 4 inches/
100mm
B 6 inches/
150mm
C 8 inches/
200mm
D 12 inches/
300mm
A 4 inches/
100mm
B 6 inches/
150mm
C 8 inches/
200mm
F 6 feet/
1.8 m
G 12 feet/
3.6 m
H 24 feet/
7.2 m
E 2 inches/
50mm
1 Aluminum
*Note:
For Installation Styles B-F, a
NEMA-1/IP-30 enclosure is standard. If
a NEMA-4/IP-65 enclosure is required
the NEMA-4/IP-65 must be specified
when placing an order.
*Note:
For (#7) Custom temperature
range, the custom range must be
specified in either Fahrenheit or Celcius
when placing an order.
*Note:
For Installation Styles B-F, a
NEMA-1/IP-30 enclosure is standard. If
a NEMA-4/IP-65 enclosure is required
the NEMA-4/IP-65 must be specified
when placing an order.
*Note:
For (#7) Custom temperature
range, the custom range must be
specified in either Fahrenheit or Celcius
when placing an order.
Installation
Probe
Length
Probe
Material
Well
Fitting
Supply
Voltage
Signal
Output
Range
Model