High temperature

△L/Lo≦

±5%

The sample shall be left for 96

±4 hours in an atmospere with

storage

a temperature of 85

±2℃ and a normal humidity.

There shall be

Upon completion of the measurement shall be made after the

no mechanical

sample has been left in a normal temperature and normal

damage.

humidity for 1 hour.

Low temperature

△L/Lo≦

±5%

The sample shall be left for 96

±4 hours in an atmosphere with

storage

a temperature of -25

±3℃.

There shall be

Upon completion of the test, the measurement shall be made

no mechanical

after the sample has been left in a normal temperature and

damage.

normal humidity for 1 hour.

Change of

△L/Lo≦

±5%

The sample shall be subject to 5 continuos cycles, such as shown

temperature

in the table 2 below and then it shall be subjected to standard

There shall be

atmospheric conditions for 1 hour, after which measurement

no other dama-

shall be made.

ge of problems

table 2

Temperature

Duration

-25

±3℃

(Themostat No.1)

Standard

atmospheric

85

±2℃

(Themostat No.2)

Standard

atmospheric

Moisture storage

△L/Lo≦

±5%

The sample shall be left for 96

±4 hours in a temperature of

40

±2℃ and a humidity(RH) of 90~95%.

There shall be

Upon completion of the test, the measurement shall be made

no mechanical

after the sample has been left in a normal temperature and

damage.

normal humidity more than 1 hour.