ENVIROMENT CHARACTERISTICS
TEST ITEM
SPECIFICATION
High temperature
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in an atmospere with
storage
a temperature of 85
±2℃ and a normal humidity.
There shall be
Upon completion of the measurement shall be made after the
no mechanical
sample has been left in a normal temperature and normal
damage.
humidity for 1 hour.
Low temperature
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in an atmosphere with
storage
a temperature of -25
±3℃.
There shall be
Upon completion of the test, the measurement shall be made
no mechanical
after the sample has been left in a normal temperature and
damage.
normal humidity for 1 hour.
Change of
△L/Lo≦
±5%
The sample shall be subject to 5 continuos cycles, then it shall be
temperature
subjected to standard atmospheric conditions for 1 hour,
There shall be
after which measurement shall be made.
no other dama-
ge of problems
Moisuture storage
△L/Lo≦
±5%
The sample shall be left for 96
±4 hours in a temperature of
40
±2℃ and a humidity(RH) of 90~95%.
There shall be
Upon completion of the test, the measurement shall be made
no mechanical
after the sample has been left in a normal temperature and
damage.
normal humidity more than 1 hour.
Test conditions:
The sample shall be reflow soldered onto the printed circuit board in every test.
Page-5/8