Mag.layers – Mag Layers USA MCI-2012 User Manual
Page 4

Temperature : +85
±2℃
Applied voltage : Rated voltage
Applied current : Rated current
Testing time : 500
±12 hours
Measurement :After placing for 24 hours min.
Temperature : +85
±2℃
Humidity : 90 to 95%RH
Applied current : Rated current
Applied voltage : Rated voltage
Testing time : 500
±12 hours
Measurement :After placing for 24 hours min.
Temperature : -25℃,+85℃
kept stabilized for 30 minutes each.
Cycle : 100 cycle
Measurement :After placing for 24 hours min.
Low
Temperature : -25
±2℃
temperature
Testing time : 500
±12 hours
Storage
Measurement :After placing for 24 hours min.
Frequency : 10 to 50 Hz
Amplitude : 1.52 mm
Dimension and times : X ,Y and Z directions
for 2 hours each.
MCI-2012-SERIES
Page-4/7
Item
Specifications
Test conditions
Vibration
Appearance : Ferrite shall not be
damaged.
High
temperature
Appearance : Ferrite shall not be
damaged.
Impedance:Within
±20% of the
initial value.
insulation resistance: >10(M
Ω)
DC resistance : standard value
inside.
Humidity
resistance
Thermal shock
MAG.LAYERS
-40℃
+85℃
30 min.
30 min.
1 cycle
30 sec