Climatic test
ITEM
SPECIFICATION
TEST CONDITION
Thermal Shock
(Temperature Cycle)
Temperature: -55
℃
~125
℃
for 30 minutes
each, 100 cycles.
Humidity Resistance
Temperature : 60
℃
Humidity: 95% RH
Time: 1000
±
12 Hours
High Temperature
Resistance
Temperature : 85
℃
±
2
℃
Time: 1000
±
12 Hours
Low Temperature
Resistance
Impedance shall be within
±
20% of the initial
value.
Temperature : -40
℃
±
2
℃
Time: 1000
±
12 Hours
1. Operating Temperature Range: -55
℃
TO +125
℃
2.
Storage Condition: The temperature should be within -40
℃
~85
℃
and humidity should be less than 75% RH.
The product should be used within 6 months from the time of delivery.
See also other documents in the category Mag Layers USA Hardware:
- GMLI-201209/12 (9 pages)
- GMPI-201205 F1 (8 pages)
- GMPI-201209 F1 (8 pages)
- GMPI-201610 F1 (8 pages)
- GMPI-252005 F1 (8 pages)
- GMPI-252010 F1 (8 pages)
- GMPI-252012 F1 (8 pages)
- GMLB-3216 A (8 pages)
- GMLB-3216 B (8 pages)
- GMLB-160808 (9 pages)
- GMLB-160808 (10 pages)
- GMLB-100505 (8 pages)
- GMLB-201209 (10 pages)
- GMLB-060303 (8 pages)
- Chip Antenna (3 pages)
- PCB Antenna (1 page)
- FPC Antenna (1 page)
- Metal Stamping Antenna (1 page)
- External Dipole Antenna (2 pages)
- Low Pass Filter (3 pages)
- Balun (4 pages)
- Diplexer (5 pages)
- Balance Filter (3 pages)
- Coupler (2 pages)
- MSI-200904CP (10 pages)
- MSI-280904CP (10 pages)
- MSI-101004PF (9 pages)
- MCI-2012 (9 pages)
- MCM-7060M (8 pages)
- MCM-9070M (8 pages)
- MCM-1211M (9 pages)
- MHSC-1608C (9 pages)
- MHSC-2012C (8 pages)
- MHSC-2520C (8 pages)
- MHQC-2520C (8 pages)
- SMB-403025 (7 pages)
- SMB-853025 (8 pages)
- MSI-700705 (9 pages)
- MSI-100705 (9 pages)
- MSI-110708 (9 pages)
- MSI-111109 (4 pages)
- MSI-131308 (4 pages)
- MSI-400404 (11 pages)
- MSI-600608 (10 pages)