Mechanical performance test, Climatic test – Mag Layers USA GMLB-3216 B User Manual
Page 7
MAG.LAYERS
GMLB-3216-B Series
R
R
R
E
E
E
L
L
L
I
I
I
A
A
A
B
B
B
I
I
I
L
L
L
T
T
T
Y
Y
Y
T
T
T
E
E
E
S
S
S
T
T
T
•
Mechanical Performance Test
ITEM
SPECIFICATION
TEST CONDITION
Solderability
More than 90% of the terminal electrode shall
be covered with fresh solder.
Solder: 96.5Sn-3.0Ag-0.5Cu
Solder Temperature: 245
±
5
℃
Flux: Rosin
Dip Time: 3
±
1 Seconds
Soldering Heat
Resistance
The chip shall not crack.
More than 75% of the terminal electrode shall
be covered with solder.
Solder temperature : 260
±
5
℃
Flux: Rosin
Dip time: 10
±
1 seconds
TYPE
W(KGF)
TIME (SEC)
GMLB-2012-M4
0.2
10
±
2
Terminal Strength
The terminal electrode shall not be broken off
nor the ferrite damaged.
W
GMLB-3216-M4
0.5
10
±
2
TYPE
A(MM)
P(KGF)
GMLB-2012-M4
1.74
0.2
Bending Strength
No mechanical damage.
The ferrite shall not be damaged.
A
Chip
P
1.0
R0.5
GMLB-3216-M4
2.0
2.0
Bending Test
Appearance: No damage
Substrate: PCB(100mm
×
40mm
×
1.6mm)
Solder: Reflow
Speed of Applying Force: 0.5mm / s
Deflection: 2mm
Hold Duration: 30 s
Vibration
Impedance shall be within
±
20% of the initial
value.
There shall be no mechanical damage.
The sample shall be soldered onto the printed
circuit board and when a vibration having an
amplitude of 1.52mm and a frequency of from 10
to 55Hz/1 minute repeated should be applied to
the 3 directions (X,Y,Z) for 2 hours each.
Drop shock
No apparent damage
Dropped onto printed circuit board from 100cm
height three times in x, y, z directions. The
terminals shall be protected.
•
Climatic test
ITEM
SPECIFICATION
TEST CONDITION
Thermal Shock
(Temperature Cycle)
Temperature cycle : -55
℃
~125
℃
for 30
minutes each.
Total: 100 cycles.
Humidity Resistance
Temperature : +60
℃
Humidity: 90% RH
Applied current: rated current
Time: 1000
±
12 hours
High Temperature
Resistance
Temperature : 80
℃
Applied current: rated current
Time: 1000
±
12 hours
Low Temperature
Resistance
Impedance shall be within
±
20% of the initial
value.
Temperature : -40
℃
±
2
℃
Time: 1000
±
12 Hours
1. Operating Temperature Range: -55
℃
TO +125
℃
2.
Storage Condition: The temperature should be within -40
℃
~85
℃
and humidity should be less than 75% RH.
The product should be used within 6 months from the time of delivery.