Mag.layers – Mag Layers USA GMPI-201205 F1 User Manual
Page 7

MAG.LAYERS
GMPI-201205 F1 series
Vibration
△
L/Lo
≦±
5%
There shall be no mechanical damage.
The sample shall be soldered onto the 
printed circuit board and when a vibration 
having an amplitude of 1.52mm and a 
frequency of from 10 to 55Hz/1 minute 
repeated should be applied to the 3 
directions (X,Y,Z) for 2 hours each. 
Drop shock
No apparent damage
Dropped onto printed circuit board from 
100cm height three times in x, y, z 
directions. The terminals shall be protected. 
•
CLIMATIC TEST
ITEM
SPECIFICATION
TEST CONDITION
Thermal Shock 
(Temperature Cycle) 
Temperature: -40
℃
,85
℃
for 30 minutes
each, 100 cycles.
Humidity Resistance
Temperature : 40
℃
Humidity: 95% RH 
Time: 1000 
±
12 HOURS
High Temperature 
Resistance 
Temperature: 85
℃
±
2
℃
Time: 1000
±
12 hours
Low Temperature 
Resistance 
No mechanical damage. 
Inductance shall be within 
±
5% of the initial
value, and Q (shall be) within
±
30% of the initial
value.
Temperature : -40
℃
±
2
℃
Time: 1000
±
12 hours
1. Operating Temperature Range: -55
℃
TO +125
℃
2. Storage Condition: The temperature should be within -40
℃
~85
℃
and humidity should be less than
75% RH. The product should be used within 6 months from the time of delivery.