Voltage Tap Settings to Table D-1 (For MIG140).

1. Check the wire and then choose the polarity and decide if the gas should be used.
2. Connect earth clamp to the work piece and be sure the connection is in good
condition and in correct polarity.
3. Protecting with helmet press the trigger to weld. Keep the contact tip and
the work piece in a distance of 5-10mm.
4. To stop welding by just releasing the trigger.
5. Close the valve of the gas bottle (if the gas is used) when the welding work finished,
then press the trigger to discharge the compressed air inside the hose.


Reference parameters for Aluminum welding (Table D-l)

Methods
of
Welding

Welding
Wire
Specificatio
ns

Shielding
GAS

Voltage/Wire Feed Rate Regulation
0.8mm 1.6mm 2.5mm 3mm

MIG
DC+

Aluminum
Welding
Wire
With
diameter at
09mm

100%
Argon

C-5

E-8

H-lO

J-10

Table D-1