Electrical installation – Lenze ECSDAxxx User Manual
Page 137

Electrical installation
Wiring of the feedback system
Digital frequency input/output (encoder simulation)
l
137
EDKCSDX064 DE/EN/FR 3.0
Wiring
ƒ
1 slave on the master:
Wire master and slave to each other directly via interface X8.
B
GND
Z
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
A
< 50 m
A
B
Z
A
A
B
Z
B
Z
X8
(ECS-Slave)
X8
(ECS-Master)
5
1
9
6
ECSXA029
Fig. 5−15
Connection of the master frequency input/output X8 (master
« slave)
Signals for clockwise rotation
Cores twisted in pairs
Assignment of plug connector X8: Sub−D 9−pole
Pin
1
2
3
4
5
6
7
8
9
Input signal
B
A
A
˘
GND
Z
Z
˘
B
Output signal
B
A
A
˘
GND
Z
Z
˘
B
0.14 mm
2
(AWG 26)
1 mm
2
(AWG 18)
0.14 mm
2
(AWG 26)