Lenze Range 7800 User Manual
Page 16

checked:
19.04.89
M3 33.0831
GB
page:
15
7.3 Description of the tiinction code
Function code
00
The display can be prograznined after mains
switch—on mains using
thls function code.
Data code
00:
Display
ot
the rotational
fieid
frequency
01:
Display
of
the motor current
(R.~4.S.).
By pressing
the SHIFT-key,
either frequency or
current display can ~e
selected
during
operation.
Functiori
code 01,
02,
03
The inverter is
set to one
of
the three prograininable rotational
tield frequencies,
by olosing the switches
S3
and/or S4.
As soon
as
S3 and/or S4 are closed,
any other set—value setting is
made
inactive.
S3
54
trequency setting
[Hz] using
function code
tactory
setting
closed
open
closed
open
closed
closed
01
02
03
10 Hz
20 Hz
30 Hz
Function code 04
The
inverter
is
set to
a fourth,
programined rotational
ffield
frequency by closing switch S5.
As soon as
S5
is
closed,
any other set-value setting,
as well as switches 53
and S4 are
inactive.
The frequency is set in Hz.
(Factory setting is
5 Hz).
Note:
At maximum
ffrequencies
higher
than 50
or 60Hz,
the rotational
field treguencies which are set
usirig tunction codes
01,
02,
03
and 04
are multiplied
according
to the maximum freguencies.
:Or example-
Maximum frequency:
150Hz
(Function code 10 data code 04)
Prograxnined flxed
fregency:
20:~iz
(Function
code
01,
02,
03
or
04:
data
code
20)
Actual fixed ffreguency:
60Hz
ET46/ffa