Scope of supply, Connections and interfaces, Status displays – Lenze ECSDExxx User Manual
Page 58
l
58
EDKCSDE040 DE/EN/FR 4.0
Scope of supply
Position
Description
Number
0
Power supply module ECSDExxx
1
2
Accessory kit with attachment material
1
Mounting instructions
1
Drilling jig
1
)
Note!
The ECSZE000X0B connector set must be ordered separately.
Connections and interfaces
Position
Description
Detailed
information
X22
Connections
l
External brake resistor
l
DC−bus voltage
l
PE
^
1
LEDs: Status and fault display
X1
Automation interface (AIF) for
l
Communication module
l
Operating module (XT keypad)
^
X2
PE connection AIF
X3
Not assigned
X4
CAN connection
l
System bus (CAN)
l
Interface for
– master control and other modules
– PC/HMI for parameterisation and diagnostics
^
X6
Connections
l
Low−voltage supply
l
Digital inputs and outputs
l
Thermostat contacts
^
S1
DIP switch
l
CAN node address (device address in the CAN network)
l
CAN baud rate
X21
Mains connection
^
Status displays
LED
Description
Red
Green
Off
On
Power supply module is enabled, no fault
Off
Blinking
Power supply module is inhibited (CINH), switch−on inhibit
Blinking, 1 Hz
Off
Fault / error (TRIP) / short−circuit braking error (KSB−TRIP) is active
Blinking, 3 Hz
Off
Message active
Blinking, 1 Hz
Blinking
Warning active with inhibited module
Blinking, 1 Hz
On
Warning active with enabled module