Codetabelle, Diagnostics – Lenze E82ZAFIC010 User Manual
Page 65

Codetabelle
Diagnostics
l
65
EDS82ZAFIC EN 2.0
C1523:
Display of all process data words from the standard device
Code
C1523
Name
Display of all process data words from the standard
device
Index
0x5A0C (23052)
Subcode
Lenze
Values
Access
Data type
1 ... 16
g
0
[1]
65535 r
U16
o Parameter set transfer
Display of the process data words 1 ... 16 that are transferred from the standard device to
the function/communication module:
Subcode
Process data word
1 FIF status word 1 (FIF−STAT1)
2 FIF status word 2 (FIF−STAT2)
3 Output frequency with slip (MCTRL1−NOUT+SLIP)
4 Output frequency without slip (MCTRL1−NOUT)
5 Apparent motor current (MCTRL1−IMOT)
6 Actual process controller value (PCTRL1−ACT)
7 Process controller setpoint (PCTRL1−SET)
8 Process controller output (PCTRL1−OUT)
9 Device utilisation (MCTRL1−MOUT)
10 DC−bus voltage (MCTRL1−DCVOLT)
11 Ramp function generator input (NSET1−RFG1−IN)
12 Ramp function generator output (NSET1−NOUT)
13 FIF−OUT.W1
14 FIF−OUT.W2
15 FIF−OUT.W3
16 FIF−OUT.W4
C1525:
Display of the current DIP switch positions (S2 ... S4)
Code
C1525
Name
Display of the current DIP switch positions (S2 ... S4)
Index
0x5A0A (23050)
Subcode
Lenze
Values
Access
Data type
−
g
0
[1]
7 r
FIX32
o Parameter set transfer
This code shows the current settings of the DIP switches S2 ... S4. These switches serve to
set the number of process and parameter data words (
¶ 30).
DIP switch
Value
S2
1
S3
2
S4
4