Parameter data transfer

Initialise PCP communication
Available PCP services

8

l

52

EDS82ZAFIC EN 2.0

Identify

The "Identify" PCP service provides information on how to identify the controller. The
controller provides the following parameters:

Designation

Value

Meaning

Name of device
manufacturer

"Lenze" (as visible string)

Company name

Device name

Visible string with 15
characters

Device name for controller and
function/communication module

Device version

Visible string with 15
characters

Software version of the device

Device name

Composition of the visible string:

ƒ

Characters 1 ... 5: Name of the controller
– 4 characters of device name
– 1 space

ƒ

Characters 6 ... 10: Name of the function/communication module
– 4 characters of device name
– 1 space

ƒ

Characters 11 ... 15: No name
– 5 space

If no function/communication module is available, the corresponding area is filled with
spaces.

Example:

8200 vector controller with communication module EMF2113IB: "8212 2113 "

Visible string

Device name
Standard device

Device name
Module

Space

8

2

1

2

2

1

1

3

1

6

11

15