2 operating conditions, 3 protective insulation, Operating conditions – Lenze E82ZAFIC010 User Manual
Page 14: Protective insulation, External measures. (see chapter "4.3, Technical data

Technical data
Operating conditions
l
14
EDS82ZAFIC EN 2.0
4.2
Operating conditions
Ambient conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 to +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 to +70 °C)
Operation
Corresponding to the data of the Lenze standard device used (see documentation
of the standard device).
Pollution
EN 61800−5−1
Degree of pollution 2
Degree of protection
IP20 (protection against accidental contact according to NEMA 250 type 1)
4.3
Protective insulation
Insulation between incoming bus and ...
Type of insulation (acc. to EN 61800−5−1)
l
8200 vector/motec power section
Reinforced insulation
l
Reference earth / PE
Functional insulation
l
Terminal X3.1/59
Functional insulation
l
Terminal X3.3/20
Functional insulation
l
Terminal X3.3/28
Functional insulation
Insulation between incoming bus and ...
Type of insulation (acc. to EN 61800−5−1)
Outgoing bus
Functional insulation
Insulation between outgoing bus and ...
Type of insulation (acc. to EN 61800−5−1)
l
8200 vector/motec power section
Reinforced insulation
l
Reference earth / PE
Functional insulation
l
Terminal X3.1/59
No electrical isolation
l
Terminal X3.3/20
No electrical isolation
l
Terminal X3.3/28
Functional insulation