3 electrical connection, 1 connection of the main motor, 2 connection of the remote-control motor – Lenze SIMPLABELT Compact Units User Manual
Page 16: Electrical connection, Connection of the main motor, Connection of the remote-control motor, Installation
Installation
16
L
BA S’belt KE EN 1.0
Stop!
The lubricant filling is adapted to the mounting position. To avoid damages to the gearbox, do not
change the mounting position indicated on the nameplate.
Caution!
Compact units in Z-design are not stable. Ensure propper support.
4.3
Electrical connection
Danger!
Electrical connections must only be carried out by skilled personnel!
4.3.1
Connection of the main motor
Connect the motor of your drive system according to the notes in the terminal box and the motor
operating instructions. Please observe the technical data on the motor nameplate pos. 2 (Fig. 1 and
Fig. 2).
4.3.2
Connection of the remote-control motor
Stop!
The remote-control motor must only be operated when the main motor is running. For testing the
functions at standstill, the momentary-contact switches must only be touched briefly.
1. Connect the remote-control motor according to the circuit diagram ( Fig. 3).
2. Check the direction of rotation in inching mode:
– Touch switch S1: the contact pin must move towards the flange.
– Touch switch S2: the contact pin must move in the opposite direction.
– If the pin does not move as indicated, reverse the motor polarity.
3. Check the limit switch:
– Actuate limit switch S3 (n
2max
) and touch S1.
– Actuate limit switch S4 (n
2min
) and touch S2.
– The contact pin must not move in either cases.
Show/Hide Bookmarks