Technical data
General data and operating conditions
l
45
EDK94AZMP45 DE/EN/FR/ES/IT 7.0
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 ... +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (−10 ... +55 °C)
Current derating at +45 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
1000 ... 4000 m amsl: current derating of
5 %/1000 m
Pollution
EN 61800−5−1
Pollution degree 2
Vibration resistance
(9.81 m/s
2
= 1 g)
Transport
IEC/EN 60721−3−2
2M2
EN 61800−2
2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s
2
200 ... 500 Hz: acceleration resistant up to 15 m/s
2
Operation
Germanischer
Lloyd
5 ... 13.2 Hz: amplitude ±1 mm
13.2 ... 100 Hz: acceleration resistant up to 0.7 g
IEC/EN 60068−2−6
10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 1 g
Mounting conditions
Mounting place
In the control cabinet
Mounting position
Vertically
Free space
The required free space results from the mounting
position and the specifications of the standard
device.
Mounting position
Standard
Side−by−side mounting; filter is directly screwed to
the left of the standard device (
^Mechanical
installation)
Variant
Top mounting; the filter is screwed on top of the
basic device (
^Mechanical installation)