Technical data, General data and operating conditions, 4technical data – Lenze E94AZMP User Manual
Page 44

Technical data
General data and operating conditions
4
l
44
EDK94AZMP45 DE/EN/FR/ES/IT 7.0
4
Technical data
4.1
General data and operating conditions
Conformity and approval
Approval
UR
UL508
Industrial Control Equipment, Underwriter
Laboratories (File−No. E219022) for USA and Canada
EAC
TP TC 020/2011
(TR CU 020/2011)
Electromagnetic
compatibility of
technical means
Eurasian Conformity
TR CU: Technical Regulation
of Customs Union
EAC
TP TC 004/2011
(TR CU 004/2011)
On safety of low
voltage equipment
Eurasian Conformity
TR CU: Technical Regulation
of Customs Union
Mains data
Mains types
With grounded neutral (TT/TN systems)
Operation permitted without restrictions
Other mains types
Observe instructions for special measures in the
documentation for the basic device!
Protection of persons and equipment
Enclosure
EN 60529
IP20
Not in the wire range of the
terminals
NEMA 250
Protection against
contact to type 1
Earth leakage current
IEC/EN 61800−5−1 > 3.5 mA AC
> 10 mA DC
Observe regulations and
safety instructions!
Insulation resistance
IEC/EN 61800−5−1 < 2000 m site altitude: overvoltage category III
> 2000 m site altitude: overvoltage category II