Mechanical installation

Installation / mounting condition

Preparation

2

6

BA 12.0031 EN 2.1

2

Mechanical installation

2.1

Preparation

ƒ It must be checked that the data given on the nameplate of the motor and in the

order confirmation text comply with the permissible explosion-proof application

conditions on site:
– Ex group
– Ex category
– Zone
– Maximum surface temperature

ƒ The use of the geared motor is only permissible at an ambient temperature of -20 °C

to +40 °C unless the nameplate bears another temperature.

2.2

Installation / mounting condition

Danger!

ƒ

Parts of the geared motor consist of aluminium and must be protected

against external shocks in order to prevent shock sparks.

ƒ

The geared motors must not be used in systems with cathodic protection!

ƒ

The geared motors must be included in the equipotential bonding of the

system.

ƒ

The installation of the geared motors must be carried out in such a way that

a sufficient dissipation of heat loss is ensured and the fan of the motor can

supply the cooling air required for safe operation.