ASPL 13.1001 DE/EN/FR/IT/ES 1.0

15

KFZ_Zeichen_EN-verdrahtung-bremse-AC-Mot-LKA

Connection of temperature monitoring

Terminal strip / terminal board
Meaning

Designation in accordance with EN

60034-8

Note

Thermal contact TCO

TB1 (S1)

Max. 250 V~

Max. 1.6 A~

TB2 (S2)

PTC thermistor

TP1 (P1)
TP2 (P2)

Thermal sensor +KTY

R1 (T1)

Observe polarity

Thermal sensor -KTY

R2 (T2)

Terminal board or terminal possible for all thermal sensors

External blower connection via external blower terminal box/motor terminal box

Terminal board

/terminal

Note

Separate fan 1~

U1

Connection to L1 - mains

U2

Connection to N - mains

Brake connection

Meaning

Terminal

designation

Add-on

AC-excited brake (rectifier)

~

Connection to L1 - mains

M

3~

~

Connection to N - mains

+

Connection to brake

-

Connection to brake

Switching contact, DC switching

Brake

BD1 (2F1)

DC terminal

BD2 (2F2)