Connection of temperature monitoring, Brake connection – Lenze 13.750 Three-phase AC motors User Manual
Page 15

ASPL 13.1001 DE/EN/FR/IT/ES 1.0
15
KFZ_Zeichen_EN-verdrahtung-bremse-AC-Mot-LKA
Connection of temperature monitoring
Terminal strip / terminal board
Meaning
Designation in accordance with EN
60034-8
Note
Thermal contact TCO
TB1 (S1)
Max. 250 V~
Max. 1.6 A~
TB2 (S2)
PTC thermistor
TP1 (P1)
TP2 (P2)
Thermal sensor +KTY
R1 (T1)
Observe polarity
Thermal sensor -KTY
R2 (T2)
Terminal board or terminal possible for all thermal sensors
External blower connection via external blower terminal box/motor terminal box
Terminal board
/terminal
Note
Separate fan 1~
U1
Connection to L1 - mains
U2
Connection to N - mains
Brake connection
Meaning
Terminal
designation
Add-on
AC-excited brake (rectifier)
~
Connection to L1 - mains
M
3~
~
Connection to N - mains
+
Connection to brake
-
Connection to brake
Switching contact, DC switching
Brake
BD1 (2F1)
DC terminal
BD2 (2F2)