Note!

A label in the terminal box shows the limit values of the

voltages for your motor.

ƒ During operation of the motors on the frequency inverter or during switching

operation on the mains

voltage peaks can occur, which can damage the motor insulation.

ƒ In order to avoid malfunctions, the limit values specified

in the table must not be exceeded:

Application of the motor on the

Limit values for voltage peaks

Max. amplitude

û [kV]

Max. rate of rise

du/dt [kV/μs]

Frequency inverter,

single-phase

0.75

5

Frequency inverter, three-phase

1.5

Mains (switching operation)

0.75

Tip!

ƒ

For switching operation on the mains you can limit the voltage peaks by

means of a suppressor circuit with RC elements or varistors (not included

in the scope of supply).

ƒ

Dimension the suppressor circuit for the respective application case!