HYDAC HDA 5500 User Manual
Page 11

10
display
Setting
Setting
range
Pre-
setting
device
Switch Point source SP 4 (SS 4)
Sensor 1 is activated to SP 4
Sensor 2 is activated to SP 4
Sen1
Sen2
Sen.1
HDA 5500 - 1 - 2 - XX - XXX
HDA 5500 - 2 - 2 - XX - XXX
HDA 5500 - 3 - 2 - XX - XXX
Sensor 3 is activated to SP 4
Difference value (Sensor 1 – Sensor 2)
is activated to SP 4
Sen3
Diff
HDA 5500 - 1 - 2 - XX - XXX
Switching mode SP 4 (SM 4)
SP 3 operates with adjustable
SP and hysteresis function
SP 3 operates in window function
SP/ Win
SP
HDA 5500 - X - 2 - XX - XXX
Switching direction SP 4 (Sd 4)
normaly open
normaly closed
ON/ OFF
ON
HDA 5500 - X - 2 - XX - XXX
Switch on delay SP 4 (Ton 4)
Delay time to aktivate the switch point,
after reaching the pressure for SP 4
0.00..99.99s
0
HDA 5500 - X - 2 - XX - XXX
Switch off delay SP 4 (Toff 4)
Delay time to switch off the switch point,
after reaching the switch back point for SP 4
0.00..99.99s
0
HDA 5500 - X - 2 - XX - XXX
Primary display (Primary)
Display value which should remain permanently
in the display:
current value Sensor 1
Minimum value Sensor 1
maximum value Sensor 1
Sen.1
Min.1
Top.1
Sen.1
for all devices
current value Sensor 2
Minimum valu Sensor 2
Maximum value Sensor 2
Sen.2
Min.2
Top.2
HDA 5500 - 1 - X - XX - XXX
HDA 5500 - 2 - X - XX - XXX
HDA 5500 - 3 - X - XX - XXX