Special function rotary switches – Grayhill Special Function Rotary Switches 50 Series User Manual
Page 4
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
Rotary Switches
CONVENTIONAL NUMBERS
Start by creating a conventional switch number
in the manner which follows:
Series & Style
Angle of Throw
Number of Decks
09A30-01-1-12N
Type of Contacts
Shorting = S
Non-Shorting = N
Positions Per Pole
Poles Per Deck
Note: No stop arrangement suffix is needed.
See Describing Stops.
Special Function Rotary Switches
Standard
Military
Style
Angle Of
No. Of
Poles Per
Positions
Shorting Or
Style
Style**
Description
Throw
Decks
Deck
Per Pole
Non-Shorting
01 to 04
1
02 to 12
N or S
01 to 04
2
02 to 06
N or S
09A
09M
Solder Lug
30°
01 to 04
3
02 to 04
N or S
01 to 04
4
02 or 03
N or S
01 to 04
5
02
N or S
01 to 03
6
02
N or S
42A
42M
Solder Lug
42S
—
Sealed
36°
01 to 04
1
02 to 10
N or S
—
42H
125° Temperature Rating
01 to 04
2
02 to 05
N or S
—
42HS
125° Temp Rating, Sealed
01 to 04
1
02 to 12
N or S
01 to 04
2
02 to 06
N or S
30°
01 to 04
3
02 to 04
N or S
44A
44M
Solder Lug
01 to 04
4
02 or 03
N or S
44S
—
Sealed
01 to 04
5
02
N or S
—
44H
125° Temperature Rating
01 to 04
6
02
N or S
—
44HS
125° Temp Rating, Sealed
45°
01 to 04
1
02 to 08
N or S
01 to 03
2
02 to 04
N or S
01 or 02
3
02
N or S
01 or 02
4
02
N
--
50C
Solder Lug
--
50CP
PC Mount
36°
01
1
02 to 10
N or S
--
50M*
Solder Lug, Sealed
2
02 to 05
N or S
--
50MP*
Sealed, PC
--
51C
Solder Lug
1
02 to 12
N or S
--
51CP
PC Mount
30°
01
2
02 to 06
N or S
--
51M*
Solder Lug, Sealed
3
02 or 03
N or S
--
51MP*
PC Mount, Sealed
4
02 or 03
N or S
*(Pull-to-Turn only) **For specifics on military qualified products, see Standard Switch Pages.
CHOICES AND LIMITATIONS
DESCRIBING STOPS
When a 1-pole switch has less than the maximum
number of positions, consider also the stop
system. Following is the arrangement for a 6
position switch with the position 1 isolated.
STOP 1P2 3 4 5 6 STOP
The word “STOP” indicates the conventional
switch stops, which limit rotation to positions 1
through 6. To isolate position 1 we insert only
one isolation post–between terminals 1 and 2.
The stop system already prevents rotation
beyond terminal 1.
In multi-pole switches, the stop system and
isolation system described for the first pole,
automatically affects the other poles. In the
example above, isolating position #1 on the first
pole isolates the first position (terminal #7) of
the second pole. See Standard Switch Pages
for a 2 pole circuit diagram for a 30° throw
switch.
Let's isolate position 1 and position 2 from all
other positions and from each other. We indicate
isolation posts as shown here:
12P1P2P3 4 5 6 7 8 9 10 11 12
To isolate just position 1, describe like this:
12P1P2 3 4 5 6 7 8 9 10 11 12
To isolate positions 1 and 2 from all other
positions, but not from each other, do this:
12P1 2P3 4 5 6 7 8 9 10 11 12
ORDERING INFORMATION
Indicate this as a SPECIAL switch to ensure
that no error is made when the order is entered.
Sample part number:
SPECIAL
09A30-04-1-12N
PULL 12P1P2P3 4 5 6 7 8 9 10 11 12
This sample part number orders a Series 9
standard style, four deck, one pole per deck,
twelve positions per pole rotary switch with non-
shorting contacts and isolation posts between
positions 12 and 1, between 1 and 2, and
between 2 and 3.
This lengthy order number is required to prevent
any possible confusion in ordering the switch.
When we receive your order, we will assign a
special “short form” part number to facilitate
future identification of this special switch. This
number is sequentially assigned as the need
arises, and is non-descriptive. A typical “short
form” special part number might be 09YY12345.
Contact Grayhill for price.
Not available through Distributors.
DESCRIBING POSITIONS
The Grayhill system for isolating positions lets
you choose the positions to be isolated. Grayhill
inserts isolation posts next to the positions to be
isolated. Consider a continuous rotation switch
of the Series 09A with a 30° angle of throw. The
terminals are listed here from 1 through 12 with
a space between each to indicate where isolation
posts might be inserted.
12 1 2 3 4 5 6 7 8 9 10 11 12