MDI/MDI-X, some old switch types might report incompatibility here it can be
switched off. (Auto MDI/MDI-X can be turned off even in the Xs systems)
NPASW mode:
Network Port Auto SWitchover
FSO: Transmition throgh FSO.
Backup: Backup channel (FSO disabled)
Auto: If NPASW mode is Auto then the actual channel chosen by the software
is ON.(FSO or backup)
NPASW time limit: Minimum time needed to switch from back up to FSO(minimum 2
seconds)
NPASW treshold LOW:switches to backup
NPASW treshold HIGH:switches to FSO
9.1.6 SNMP Setup
One of the main features of the device is the SNMP(Simple Network Monitoring
Protocol). The SNMP settings can be set on this page.
Trap address: The IP address of the SNMP trap over the network.
Trap events in the system you have
possibility to setup three different trap
event.
For further details on the trap event see
Trap event list chapter of this book. In this section there are the settings of the SNMP
Agent.
SNMP trap address: IP address of the
SNMP tarp computer
Read Community and Read Write
community To the setup of the Read
and the Read-Write community, the
preset value is public
Agent UDP Port the SNMP agent UDP
port number (1…1000) the preset value