TROUBLE SHOOTING GUIDE

REASON

LOW

PRESSURE

HIGH

PRESSURE

LOW

VACUUM

EXCESSIVE

NOISE

OVER

HEATING

WON'T

START

Dirty Filter

x

x

Dirty Muffler

x

x

x

Dirty Valves

x

x

Damaged Valves

x

x

x

x

Worn/Damaged Cup

x

x

Improper Cylinder
Shimming

x

x

x

x

x

x

Leaky Hose

x

x

Leaky Check Valve

x

Plugged Vac. or
Press. Line

x

x

x

x

x

Low Voltage

x

x

x

x

Leaky Relief Valve

x

x