beautypg.com

Warning – Gast 82R Series User Manual

Page 4

background image

It is your responsibility to:

• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure is released from product

before starting maintenance.

MAINTENANCE

Disconnect electrical power supply cord before

performing maintenance on this product.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Electrical Shock Hazard

WARNING

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Clean this product in a well ventilated area.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

Check that all external accessories such as relief valves

and gauges are attached to cover and are not damaged

before re-operating product.

Check intake and exhaust filters after first 500 hours of

operation. Clean filters and determine how frequently

filters should be checked during future operation. This

one procedure will help to assure the productʼs

performance and service life.

SHUTDOWN PROCEDURES

It is your responsibility to follow proper shutdown

procedures to prevent product damage.

NEVER ADD OIL TO THIS OIL-LESS PUMP.

Proper shutdown procedures must be followed to

prevent pump damage. Failure to do so may result in

premature pump failure. Gast Manufacturing Rocking

Piston Oil-Less Pumps are constructed of ferrous

metals or aluminum which are subject to rust and

corrosion when pumping condensable vapors such as

water. Follow the steps below to assure correct storage

and shutdown between operating periods.

1. Disconnect plumbing.

2. Operate product for at least 5 minutes without

plumbing.

3. Run at maximum vacuum for 10 to 15 minutes.

4. Repeat step 2.

5. Disconnect power supply.

6. Plug open ports to prevent dirt or other

contaminants from entering product.

Gast will NOT guarantee field-rebuilt product

performance. For performance guarantee, the product

must be returned to a Gast Authorized Service Facility.

Service Kit contents vary. Most contain gasket and filter

parts.

SERVICE KIT INSTALLATION

Disconnect electrical power supply cord before

installing Service Kit.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before installing Service Kit.
Vent all air lines to release pressure or vacuum.
Failure to follow these instructions can result in

death, fire or electrical shock.

WARNING

Electrical Shock Hazard

1. Disconnect electrical power supply to unit.

2. Vent all air lines.

3. Remove filter cover.

4. Check filter felt. Replace felt if it is covered with

contamination or shows signs of increasing

differential pressure.

5. Reinstall felt and filter cover.

4