It is your responsibility to operate this product at

recommended pressures or vacuum duties and room

ambient temperatures. Do not start against a vacuum

or pressure load.

Start Up

If motor fails to start or slows down significantly under

load, shut off and disconnect from power supply. Check

that the voltage is correct for motor.

OPERATION

WARNING

Injury Hazard

Use only recommended air handling parts acceptable

for pressure not less than 70 psi.

Keep fingers and objects away from openings and

rotating parts.

Product surfaces become hot during operation,

allow product surfaces to cool before handling.

Do NOT direct air stream at body. Air stream from

product may contain solid or liquid material that can

result in eye or skin damage, wear proper eye

protection.

Do NOT spray flammable or combustible liquid.

Failure to follow these instructions can result in

burns, eye injury or other serious injury.

Minimum gage for extension cords

Amps

Volts

Length of cord in feet

120v

25 50

100 150 200 250 300 400 500

240v

50 100 200 300 400 500 600 800 1000

0-2

18 18

18

16

16

14

14

12

12

2-3

18 18

16

14

14

12

12

10

10

3-4

18 18

16

14

12

12

10

10

8

4-5

18 18

14

12

12

10

10

8

8

5-6

18 16

14

12

10

10

8

8

8

6-8

18 16

12

10

10

8

6

6

6

8-10

18 14

12

10

8

8

6

6

4

10-12

16 14

10

8

8

6

6

4

4

12-14

16 12

10

8

6

6

6

4

2

14-16

16 12

10

8

6

6

4

4

2

16-18

14 12

8

8

6

4

4

2

2

18-20

14 12

8

6

6

4

4

2

2

MAINTENANCE

Disconnect electrical power supply cord before

performing maintenance on this product.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

Electrical Shock Hazard

WARNING

An undersized cord is a potential fire hazard, and will

cause a drop in line voltage resulting in loss of power

causing the product to overheat. The table indicates

the correct size cord for length required and the ampere

rating listed on the product nameplate. If in doubt, use

the next heavier gage cord. The smaller the gage

number, the heavier the wire gage.

3

SHUTDOWN PROCEDURES

It is your responsibility to follow proper shutdown

procedures to prevent product damage.

NEVER ADD OIL TO THIS OIL-LESS PUMP.

Proper shutdown procedures must be followed to

prevent pump damage. Failure to do so may result in

premature pump failure. Follow all the steps to assure

correct storage and shutdown between operating

periods.

It is your responsibility to:

• Regularly inspect and make necessary repairs to

product in order to maintain proper operation.

• Make sure that pressure and vacuum are released

from product before starting maintenance.

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Clean this product in a well ventilated area.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

1. Disconnect plumbing.

2. Operate product for at least 5 minutes without

plumbing.

3. Run at maximum vacuum for 10 to 15 minutes.

4. Repeat step 2.

5. Disconnect power supply.

6. Plug open ports to prevent dirt or other

contaminants from entering product.

Extension cords:

Use only a 3-wire extension cord that has a 3-blade

grounding plug. Connect extension cord plug to a

matching 3-slot receptacle. Do not use an adapter.

Make sure your extension cord is in good condition.

Check that the gage wire of the extension cord is the

correct size wire to carry the current this product will

draw.