Disposal

(Please note current regulations)

Parts of the rotary vane pumps and

compressors, shafts, iron or aluminum

castings, plastic or glass parts or bearings,

may be recycled as scrap materials.

P

Puum

mp

p D

Diissaasssseem

mb

bllyy::

1. Remove fan, fan guard and (4) end cap screws.

2. Remove dead end plate.

3. Check for scoring on end plate, rotor and body.

Surfaces should be smooth. If severe scoring is

visible, contact an Authorized Service Facility

4. Remove vanes

5. Clean all surfaces with Gast recommended Flushing

solvent and dry well.

Pump Re-assembly

6. Apply a light coat of Gast recommended Oil Part

#AD220 (an equivalent 10 wt. high detergent oil can

alsoo be used) to vanes.

7. Re-install vanes, noting proper direction of beveled

edge (refer to exploded view)

8. Install dead end plate and install dead end plate bolts

loosely.

9. Install bearings into dead end plate; be sure to press

inner race of bearing when installing.

10. Reassemble end cap screws, fan guard and fan.

11. Verify unit rotates freely by hand before re-

connecting power.

12. Before putting pump into service, ensure that any

external accessories have not been damaged.

13. Reconnect power.

14. Check for proper rotation if unit is 3-phase.

If pump fails to produce proper vacuum or pressure, or is

excessively noisy, turn off and return unit to an Authorized

Service Facility.

Gast will NOT guarantee field-rebuilt product

performance. For performance guarantee, the product

must be returned to a Gast Authorized Service Facility.
Service Kit contents vary. Most contain vanes, gaskets

oiler wick and filter elements.

SERVICE KIT INSTALLATION

Disconnect electrical power supply cord before
installing Service Kit.

If product is hard wired into system, disconnect
electrical power at the circuit breaker or fuse box
before installing Service Kit.

Disconnect air supply and vent all air lines to
release pressure or vacuum.

Failure to follow these instructions can result in
death, fire or electrical shock.

WARNING

Electrical Shock Hazard

W

Wee hhaavvee G

Gaasstt C

Ceerrttiiffiieed

d S

Seerrvviiccee

C

Ceenntteerrss tthhrroouugghhoouutt tthhee w

woorrlld

d..

FFoorr tthhee m

moosstt uup

p--ttoo--d

daattee lliissttiinngg,,

ccoonnttaacctt oonnee ooff oouurr ssaalleess ooffffiicceess ::

G

Gaasstt M

Maannuuffaaccttuurriinngg,, IInncc..

2300 S. Highway M139

Benton Harbor, MI 49022

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

G

Gaasstt HHoonngg KKoonngg

Unit 12, 21/F, Block B

New Trade Plaza

6, On Ping Street, Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

Gast Group Limited,

United Kingdom

Unit 11, The I O Centre

Nash Road

Redditch, B98 7AS

United Kingdom

ph: +44 (0) 1527

Fax: +44 (0) 1527

www.gastmfg.com

This manual is related to the following products: