beautypg.com

Gast 1423 Series Oilless Vacuum Pumps and Compressors User Manual

Page 8

background image

TROUBLESHOOTING CHART

www.gastmfg.com

ISO 9001 & 14001 CERTIFIED

PART NO. 70 - 290 G375PL (REV-J)

Low

High

Pump

Motor

Reason and remedy

Vacuum Pressure Vacuum Pressure Overheat Overload for problem.

At pump

Filter dirty.

Clean or replace.

At pump

Muffler dirty.

Clean or replace.

At pump

Vacuum line collapsed.

Repair or replace.

Relief valve set too high.

Inspect and adjust.

Relief valve set too low.

Inspect and adjust.

At pump At pump

Plugged vacuum/pressure line.

Inspect and repair.

Vanes sticking.

Clean or replace.

Vanes worn.

Replace.

Shaft seal worn.

Replace.

Dust or offset powder in pump.

Inspect and clean.

Motor not wired correctly.

Check wiring diagram and line voltage.

World Headquarters
P.O. Box 97

2300 S. Highway M139

Benton Harbor, MI 49023-0097

Ph: 269/926-6171

FAX: 269/925-8288

www.gastmfg.com

Gast Group Limited,
United Kingdom
Unit 11, The I O Centre

Nash Road

Redditch, B98 7AS

United Kingdom

ph: +44 (0) 1527 504040

Fax: +44 (0) 1527 525262

www.gastmfg.com

Gast Hong Kong
Unit 12, 21/F, Block B

New Trade Plaza

6, On Ping Street, Shatin

N. T. Hong Kong

Ph: (852) 2690 1066

Fax: (852) 2690 1012

www.gasthk.com

FAX: 269/925-8288

www.gastmfg.com