Section 1
Tools:

10mm spanner.
Rule.
Sharp craft knife.

Section 2
Positioning:
• The vent can only be positioned where there are no obstructions and away from

the corners, for example, in the centre back panel, opposite the door.

• The best position is low down to provide a through draught with the roof vent.
• To install the vent, the existing glazing panel must be removed and cut to size

after fitting the vent.

Section 3
Installation:
• Remove the existing polycarbonate panel

from the chosen position.

• From the inside, insert two crop-head

bolts into each glazing upright, at each
side of the opening.

• Bolt the vent loosely to the uprights, with

the handle to the right, as at Fig A.

• Add the PVC profile strips to

each long edge of the
polycarbonate sheets provided
and insert the sheets into the
vent slots.

• Squeeze the soft metal flanges

on each section of the vent to
grip the polycarbonate sheet
firmly. Fig B.

• Check the position and

mechanism and tighten all nuts.

• Measure the remaining gap and carefully cut the removed polycarbonate sheet to

fit, using a sharp craft knife and a straight edge.

Customer Helpline: 01406 372227

Fig A

Fig B

L3

L4

Squeeze

Squeeze

Glazing
upright