5. Two models are available. One specific model for propane (LP), and one for natural gas.
Use the correct gas type for your home. This unit is not field convertible.
6. If these gas logs are for use with propane gas, do not place propane supply tank(s) inside
any structure. Locate propane supply tank(s) outdoors.
7. If you smell gas:
- Shut off gas supply.
- Do not try to light any appliance.
- Do not touch any electrical switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbor’s phone . Follow the gas suppliers
instructions.
- If you cannot reach your gas supplier, call the fire department.
8. “This heater shall not be installed in a confined space or unusually tight construction
unless provisions are provided for adequate combustion and ventilation air”. See
Section V-Producing Adequate Ventilation. See page 18.
9. Surface of gas logs becomes very hot when operating. Keep children and adults away
from hot surface. Gas logs will remain hot for some time after shutdown. Allow surface
to cool before touching.
10. Never place any objects on these gas logs .
11. These gas logs MUST NOT BE USED with glass doors in a closed position.
12. If equipped, fresh air dampers must be closed.
13. Keep appliance area clean and free from combustible materials, gasoline, and other
flammable vapors and liquids. “Keep burner and control compartment clean. See
installation and operating instructions accompanying heater.”
14. If burner shuts off, do not relight until you provide fresh outside air. If burner keeps
shutting off, have unit serviced.
15. An unvented room heater having input rating of more than 10,000 BTU per hour shall
not be installed in a bedroom or bathroom.
16. Maintain clearance around air openings.
17. Do not use the appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of control system and
any gas control which has been under water.
18. Turn off the gas logs and let cool before servicing.

WARNING

This appliance is equipped for (natural or propane) gas.
Field conversion is not permitted.