beautypg.com

Troubleshooting – New Buck Corporation CR8T User Manual

Page 30

background image

TROUBLESHOOTING

WARNING

TURN OFF, UNPLUG HEATER AND LET COOL BEFORE SERVICING.

ONLY A QUALIFIED SERVICE PERSON SHOULD SERVICE AND

REPAIR HEATER.

CAUTION

NEVER USE A WIRE, NEEDLE, OR SIMILAR OBJECT TO CLEAN ODS/
PILOT. THIS CAN DAMAGE ODS/PILOT.

OBSERVED POSSIBLE

PROBLEM CAUSE SOLUTION

When igniter button is pressed, 1. Igniter electrode positioned 1. Replace igniter
there is no spark at ODS/PILOT incorrectly
2. Igniter electrode broken 2. Replace igniter
3. Igniter electrode not 3. Reconnect igniter cable
connected to igniter cable
4. Igniter cable pinched or wet 4. Free igniter cable if pinched
by any metal or tubing. Keep
igniter cable dry.
5. Broken igniter cable 5. Replace piezo igniter cable.
6. Bad piezo igniter 6. Replace igniter cable

OBSERVED POSSIBLE SOLUTION
PROBLEM CAUSE

When igniter button is pressed, 1. Gas supply turned off or 1. Turn on gas supply or open
there is spark at ODS/PILOT but manual shutoff valve is manual shutoff valve
no ignition. closed
2. Control knob not in “PILOT” 2. Turn control knob to “PILOT”
position position
3. Control knob not pressed in 3. Press in control knob while in
while in “PILOT” position “PILOT” position.

26