Euramco Safety VX700 User Manual
Page 19

9.0
Troubleshooting
1. Motor turns over but won't start
Fuel Tank is out of gasoline.
Fuel Valve not open.
Choke not set.
2. Motor does not turn over and does not start
Emergency OFF Switch not turned ON
The combination of vehicle tilt plus the fan tilt exceeds 20
˚
Battery is discharged
Circuit breaker on the Control Panel has tripped and needs to be reset
3. Scene light does not light
Halogen lamp is burned-out and needs to be replaced
Scene Light Switch not turned ON
4. Fan does not tilt
Control Panel Circuit Breaker has tripped and needs to be reset
5. Fan does not tilt down
Fan is already at the down limit. Tilt fan up.
6. Fan does not tilt up
Fan is already at the upper limit. Tilt fan down.
7. Mister nozzles do not spray
Water supply line not connected to VX700.
Water supply source is not turned ON.
VX700 Water Valve is not turned ON.
Water filter clogged and needs to be replaced.
8. Mister nozzles spray pattern is weak or intermittent
Low water pressure to the VX700.
Clogged water filter.
Bent atomizer wire on nozzle.
9. Hand brake does not hold trailer in place
Adjust hand brake cap CW until trailer does not move.
Page 18