8.0
Operation
8.1
VX700 Control Features, (Continued)
8.1.3. Motor
3. Throttle
The Throttle level controls the speed / RPM of the motor / fan blade
assembly.
4. Ignition Switch
The keyed ignition switch has three (3) functions: 1.) Turn motor OFF, 2.)
Start motor, and 3) Motor Run.
Some Ignition Switch functions are wired to the VX700 Control Panel to
provide enable motor and kill motor operation for remote safety control
considerations.
Two (2) ignition keys are provided with each VX700.
5. Hour Meter
The hour meter records and displays total motor run time. This cumulative
hour reading is intended to be use in support of recommended maintenance
schedules .
6. Oil Alert
The Oil Alert feature kills engine operation should the oil level in the
crankcase drop below recommended levels. An LED light on the motor
control panel provides indication when engine failed as a result of low oil
level.
A low oil condition also can be created with excessive motor tilt. The
combine tilt of both vehicle and motor must not exceed 20
˚.
8.1.4
Fan
1. Impeller
The Impeller is a 28", seven blade, lightweight, state-of-the-art design. As
used on the VX700 the Impeller can provide as much as 60,000 CFM for a
PPV applications at a thrust of 55 lbs of force.