Fig. 3: Dimension drawing of handwheels HWA and HWB
Technical data
Parameters
Value
Pulses per revolution
2 x 25 (G12) oder 2 x 100 (A05, G05)
Detent positions
100
Housing material
Plastic/metal
Weight
HWA 100 g / HWB 130 g
Detent mechanism
Mechanical
Shaft loading, axial, max.
25 N
Shaft loading, radial, max.
40 N
Mechanical service life, min.
1 x 10
6
U
Operating temperature
0 °C ... +50 °C
Storage temperature
-20 °C ... +50 °C
Humidity, max.
80 % (condensation not permissible)
Degree of protection to the front
In accordance with EN 60529 / IEC 529
IP 65
In accordance with NEMA
250-12
Output circuit Push-pull
Output stage
G05
G12
Pin assignment
Output signals
A, B
Operating voltage U
B
DC 5 V ± 10 %
DC 12 V ± 10 %
Operating current, no load, max.
80 mA
Output specifications
Output voltage
HIGH (1), min.
4.0 V / 20 mA
LOW (0), max.
0.5 V / 20 mA
Output current per output, max.
20 mA
Output signals
100 pulses
25 pulses
Home position area
Home position areas
Output circuit RS422
Output stage
A05
Output signals
Pin assignment
Output signals
A, /A, B, /B
100 pulses
Operating voltage U
B
DC 5 V ± 10 %
Operating current, no load, max.
80 mA
Output specifications
RS422A
Home position area
90˚
360˚
A
B
90˚
360˚
A
B
+U
B
0V A B
+5V 0V A A B B
90˚
360˚
A
/A
B
/B
Front panel cut-out
3,3 / 1.7 tief
9,2
19
51
60
30
25,5
15
21,8
26
16,5
48
66
±1
1,5 - 2,0
Front panel cut-out
4,5
62
±0,5
12
0
3
x
12
0
(=3
60
)
72
±0
,1
60
±0,5
72
15
25,4
38
28,5
M4
M4x8 (3x)
53
72
80
±1
41,5
Handwheel HWA
Handwheel HWB
Control panel
thickness
3.0 mm, max.
Control panel
thickness