beautypg.com

Technical data, general, Accessories, Technical data on the components – EUCHNER HBAS User Manual

Page 4

background image

Operating Instructions for HBAS Hand-Held Pendant Stations

EUCHNER GmbH + Co. KG

Kohlhammerstraße 16

D-70771 Leinfelden-Echterdingen

Tel. +49/711/75 97-0

Fax +49/711/75 33 16

www.euchner.de

[email protected]

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information.

© EUCHNER GmbH + Co. KG

0

92771-05-01/08

Technical data, general

Parameters

Value

Housing material

Polycarbonate

Color

Gray RAL 7040/

Black RAL 9004

Operating temperature

0 °C to +50 °C

Storage temperature

-20 °C to +50 °C

Humidity, max.

80 %

Condensation not permissible

Degree of protection according to
EN 60529 / IEC 529

IP 65

NEMA

250-12

Weight

860 g

Resistance to vibration
Vibrations (3 axes)

DIN / IEC 68-2-6

Shock (3 axes)

DIN / IEC 68-2-27

EMC protection requirements

EN 61000-6-2

in accordance with CE

EN 61000-6-4

Electrical connection
Operating voltage U

B

DC

24 V ± 20%

Operating current, max.

100 mA

Power consumption max.

2.4 VA

Communications interface
Type RS422A

See manual

Technical data on the components

Pulse generator
Output circuit

See manual

EMERGENCY STOP

Value

Standard

EN ISO 13850

Switching elements

Max. 2 NC

Utilization category

DC-13

acc. to IEC 60947-5-1

U

e

=30 V / I

e

= 3 A

2-stage enabling switch

Value

Switching element

1 NO

Maximum DC switching voltage

30 V

Maximum switching current

0.1 A

3-stage enabling switch

Value

Switching element

2 NO

Utilization category

DC-13

acc. to IEC 60947-5-1

U

e

=24 V / I

e

= 0.1 A

Breaking capacity max.

250 mW

Switching current min.

5 mA

Switching current max.

100 mA

Other components
See associated operating instructions, EUCHNER catalog for hand-
held pendant stations or www.euchner.de

Accessories

See EUCHNER catalog for hand-held pendant
stations or www.euchner.de