beautypg.com

Operating instructions enabling switch zsb, Technical data – EUCHNER ZSB User Manual

Page 6

background image

Operating Instructions Enabling Switch ZSB

EUCHNER GmbH + Co. KG Kohlhammerstraße 16 D-70771 Leinfelden-Echterdingen Tel. +49/711/75 97-0 Fax +49/711/75 33 16 www.euchner.de [email protected]

Figure 3: Dimensional drawing enabling switch ZSB and holder for enabling switch

ZSB070904
ZSB072645
ZSB072403

ZSB077029
ZSB085058

ZSB2A2G..A
ZSB2A2G..C
ZSB077040

Holder for
enabling switch
ZSB2A2G..A
ZSB2A2G..C
ZSB077040

Height 30 mm

Technical data

Parameters

Value

Housing material

Plastic

Degree of prot. acc. to IEC 60529

IP65

Mechanical life min.

Position 1-2-1

1x10

5

cycles

Position 1-2-3-1

1x10

5

cycles

Ambient temperature

-5 ... +50 °C

Degree of contamination (external, according to EN 60947-1)

3 (industrial)

Switching elements

See Figure 1

Switching principle

Slow-action contact element

Switching current, min., at 24 V

1 mA

Switching voltage, min., at 10 mA

12 V

Rated impulse withstand voltage

U

imp

= 0.8 kV

Rated insulation voltage

U

i

= 250 V

Rated short-circuit current

100 A

Reliability figures acc. to EN ISO 13849-1

B

10d

5 x 10

5

Enabling switches

Additional elements

Utilization category according to EN 60947-5-1

AC-15 2 A 24 V

AC 24 V 400 mA

DC-13 2 A 24 V

DC 24 V 100 mA

Short circuit protection for 24 V

1)

2 A gG

0.1 A gG

Type

ZSB2A2G..A

ZSB2A2G..C

ZSB077040

ZSB077029

ZSB070904/ZSB072403

ZSB085058

ZSB072645

Special features

Direct connection to safety

switch TZ...-C1803 possible

Additional elements

2 buttons (NO contacts)

2 buttons (NO contacts)

2 buttons (NO contacts)

2 illum. buttons (NO contacts)

2 illum. buttons (NO contacts)

T1 minus, T2 plus

T1 minus, T2 plus

T1 minus, T2 plus

T1 minus, T2 plus

T1 minus, T2 plus

1 key-operated rotary switch

}(NO contacts)

Connection

Connection cable

Plug connector

Plug connector

Plug connector

Plug connector

12-pin

12-pin

12-pin

17-pin

U

i

= 32 V at

U

i

= 32 V at

U

i

= 32 V at

U

i

= 32 V at

Degree of contamination 2

Degree of contamination 2

Degree of contamination 2

Degree of contamination 2

Connection cable

enabling switch

4 x 0.5 mm²

4 x 0.5 mm²

4 x 0.5 mm²

4 x 0.5 mm²

4 x 0.5 mm²

(individually screened) +

(individually screened) +

(individually screened)

(individually screened) +

(individually screened) +

4 x 0.5 mm²

4 x 0.5 mm²

4 x 0.5 mm²

4 x 0.5 mm²

Cable length max.

25 m

25 m

25 m

25 m

25 m

Additional elements

8 x 0.14 mm²

8 x 0.14 mm²

4 x 0.5 mm²

8 x 0.14 mm²

8 x 0.14 mm²

Weight

Approx. 1.1 kg

Approx. 1.1 kg

Approx. 1.1 kg

Approx. 1.5 kg

Approx. 1.5 kg

1) In case of operating voltages other than DC 24 V, the short circuit protection must be dimensioned accordingly and checked.