classic mode / klassischer Modus

unterstrichene Werte sind anwählbar

underlined data can be selected

advanced display mode / erweiterter Display-Modus

Basic Operation

The device starts in the traditional mode. You can switch between the two modes with ESC or OK. In the advanced mode the
cursor is moved by both arrow buttons. Pushing OK puts you to the superior menue (in the drawing one step to the right side).
ESC puts you back to the previous menu. To edit data you first mark them with the cursor and then select them with OK, change
them with the arrow buttons and finally apply them with OK. Pushing ESC cancels the editing.

Grundlegende Bedienungshinweise

Das Gerät startet im klassischen Modus. Mit

ESC oder OK kann zwischen dem klassischen und dem erweiterten Modus

gewechselt werden. Im erweiterten Modus wird der Cursor mit den beiden Pfeil-Tasten bewegt.

OK wechselt ins nächsthöhere

Menü.

ESC wechselt zurück ins vorherige Menü. Die zu editierenden Werte zunächst mit dem Cursor markieren, dann mit OK

auswählen, mit den Pfeiltasten verändern und schließlich mit

OK übernehmen. ESC bricht das Editieren ab.

kursive Einträge sind nicht immer vorhanden

items in italic are not always available

TEACH SAFETY
SAFE OUTPUT CH
SAFE COUPLING
START/STOP
CLEAR SAFE CFG
PIN
SAFE CHIPCARD
PROTECT
SAFE SUBST VAL

PROFIBUS
QUICK SETUP

SETUP
DISPLAY CONTRAST

AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST

SAFE COUPLING
ON CHANNEL

2

ADR

A S - I S A F E T Y

A S - I S A F E T Y

SAFE SUBST VAL
SUBSTITUTE

CHANGE

CHANGE PIN
ENTER NEW PIN

0000
0000
OK

SELECT BANK

A
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

ENTER PIN

0000
OK

BANK A KONFIG
COMPLETE
CONFIGURATION:
RELAIS IMMER AN
MON. VER. : 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2

COPY BANK A TO
MONITOR
COMPLETE
CONFIGURATION:
RELAIS IMMER AN
MON. VER. : 3.0
RELEASED:
BY ROLF BECKER
ON 2008/01/21
AT 13:52
RELEASE CODE:
B1D2
------------------------------
RELEASE CODE?
1BDF

OK

CLEAR SAFE CFG

ENTER PIN
0000
OK

SELECT BANK

A
OK

SELECT BANK

A
CLEAR

START/STOP
ENTER PIN

0000
OK

CHANGE PIN
ENTER PIN

0000
OK

SAFE CHIPCARD
ACTIVE: BANK B

VIEW
CARD -> MONITOR
MONITOR -> CARD
CLEAR CODES
CLEAR SAFE CARD

STOP MONITOR?

OK

START MONITOR

OK

CLEAR SAFE CFG

CLEAR

PROTECT
ENTER PIN

0000
OK

DOWNLOAD
NOT ALLOWED

CHANGE

TEACHING CODES
CLOSE CONTACTS

AS-I 1:
|

1-OK

2-RX |

3-RR

.... |
30-DC | 31-DC

AS-I 2:
|

1-OK

2-RX |

3-RR

.... |
30-DC | 31-DC
....
HELP
NO SAFETY SL
MS MISSING SLAVE
X CH OK
R CH RELEASED
OK CODE LEARNED
ER CODE ERROR
DC DUPL.CODE

TEACH CODES
ENTER PIN

0000
OK

TEACH CODES
COMPLETE
SINGLE SLAVE
COUPLING SLAVE
SNGL SLAVE CODE

SAFE OUTPUT
CHANNELS
CH 1: ON
CH 2: OFF
...
CH 16: OFF

TEACHING CODES
SLAVE ADDR.

2(1)

OK

ESC

OK

TEACH CODES
ENTER PIN

0000
OK

SLAVE ADDR. 2
ENTER CODE (1)

00000000

ESC

OK

COUPLING SLAVE
SLAVE ADR

2(1)

ESC

OK

AS-I CIRCUIT 1
AS-I CIRCUIT 2

START/STOP
STOP

CHANGE

Commissioning / Inbetriebnahme