beautypg.com

Obar s 1 w, Lcd diagnostic codes, Page 6 – Braun NUVL603C User Manual

Page 8: Diag button, Nuvl855c only)

background image

Page 6

103

102
103

103

103

103

103

103

103

103

103

103

103

102

243R

103

103

103

103

103

103

102

103

103

103

102

102

102

220

CHA

6C5

220

CHA

6C5

100 VHA

6C5

220 35A

5Q6

321

321

321

V104

V104

V104

C105

V104

V104

102

102

V104

V104

V104

V104

102

102

V104

106 E

330

SOMC1601

8.00M

8.00M

MP916

0.010Ω
.5% R

6H23EM

6H23EM

D7

D8

D5

D6

D3

D4

D2

D1

C20

U8

C4

R15

R14

R8

L_DN

B_UP

L_OUT

L_UP

B_DN

L_IN

C3

C2

R4

R2

R1

R6

R7

SW1

SW2

50# CAL

O_BAR

GROUND L

V

L

R9

R10

C1
1

C10

R42

C1

R32

C21

U3

U2

ZD3

R27

R29

R31

cycle

diag

U5

CLOSECLOSE

OPEN

D10

D11

U17

U7

R37

R36

C5

C15

R33

R11

C22

D13

U18

C9

C8

C14

U12

B LIGHT


A

Magnetic

Remote

U21

HAND-1

HAND-2

INLK-1

D/S

U/D

J1

J2

R28

D26

D25

D24

D23

R26

R16

R1

U15

C6

U14

C7

R13

R20

R19

R18

U16

R39

R5

K

J

I

H

G

L

A

B

C

D

Lift Devices

4 3 2 1

Door

Operator

RL1

1

RL10

IN L

H

MA
T

C16

220

35A

5Q6

U20

R25

C12

D12

VR3

FS1

U19

RL9

R34

C13

FS2

FS8

VR1

VR2

LIGHT

ALARM

PUMP

VA
LV
E

L_IN

L_OUT

B_UP

B_DN

R40

FS7

D9

FS10

FS9

FS5

FS4

FS3

FS6

U9

R3

D19

D18

D21

D20

D16

D17

D15

D14

RL1

RL2

RL3

RL4

NUVL

CONTROLLER REV

-3.1-1

The Braun Corporation

PWR-IN

1802

1002

R43

R41

U22

102

R38

FS1

1

OH

IN

GND

12V

-B

LIGHT

ALARM

CONTRAST

OBAR S 1

W

All basic functions (UP,
DOWN, STOW and
DOOR) should show a
value of 1 when activated
via a controlled input
(Hand-held Pendant,
Magnetic, Remote Entry
or 3rd Station Controls).

STOW

DOWN

UP

DOOR

LCD Diagnostic Codes

To change the LCD display from cycle count to diagnostic
mode, press the “diag” button on the control board (see
illustration at right). When finished, press button again to
return to cycle count mode. When all of the harnesses
are correctly connected to the control board, the values
shown in the chart below will display when the correspond-
ing action is taken. “1” will appear to the right of the switch
or sensor name on the LCD module when activated as
shown. If any other value appears on the LCD screen
during the specific diagnostic procedure, verify that the
correct harness is properly connected to both the control
board and the associated lift harness. Repeat the harness
diagnostic procedure. If an incorrect value is still present
after checking the harness and connections, contact The
Braun Corporation Product Support Department.

Hand-held Pendant

diag Button

V104

102

102

102

D7

D8

D5

D6

D3

D4

D

2

R31

cycle

C6

C

OBAR S 1

W

NUVL Control Board

LCD Display

Moving Out
Of Cassette

Moving Up

From Stow

At Floor

Level

Moving Down

From Stow

Ground

Level

Ground Level

OB Out

STLV SW

1

1

LOUT SW

1

FOUT SW

1

1

1

1

1

FLV

SW

1

OBAR SW

1

1

1

1

1

1

MAT

SW

= 1 when mat is activated.

DO

SW

= 1 when door is full open or pin 3 and pin 4 are jumpered.

*IBAR SW

= 1 when inboard locator is activated

Stowed

*(NUVL855C only)