Obar s 1 w, Lcd diagnostic codes, Page 6 – Braun NUVL603C User Manual
Page 8: Diag button, Nuvl855c only)
Page 6
103
102
103
103
103
103
103
103
103
103
103
103
103
102
243R
103
103
103
103
103
103
102
103
103
103
102
102
102
220
CHA
6C5
220
CHA
6C5
100 VHA
6C5
220 35A
5Q6
321
321
321
V104
V104
V104
C105
V104
V104
102
102
V104
V104
V104
V104
102
102
V104
106 E
330
SOMC1601
8.00M
8.00M
MP916
0.010Ω
.5% R
6H23EM
6H23EM
D7
D8
D5
D6
D3
D4
D2
D1
C20
U8
C4
R15
R14
R8
L_DN
B_UP
L_OUT
L_UP
B_DN
L_IN
C3
C2
R4
R2
R1
R6
R7
SW1
SW2
50# CAL
O_BAR
GROUND L
V
L
R9
R10
C1
1
C10
R42
C1
R32
C21
U3
U2
ZD3
R27
R29
R31
cycle
diag
U5
CLOSECLOSE
OPEN
D10
D11
U17
U7
R37
R36
C5
C15
R33
R11
C22
D13
U18
C9
C8
C14
U12
B LIGHT
A
Magnetic
Remote
U21
HAND-1
HAND-2
INLK-1
D/S
U/D
J1
J2
R28
D26
D25
D24
D23
R26
R16
R1
U15
C6
U14
C7
R13
R20
R19
R18
U16
R39
R5
K
J
I
H
G
L
A
B
C
D
Lift Devices
4 3 2 1
Door
Operator
RL1
1
RL10
IN L
H
MA
T
C16
220
35A
5Q6
U20
R25
C12
D12
VR3
FS1
U19
RL9
R34
C13
FS2
FS8
VR1
VR2
LIGHT
ALARM
PUMP
VA
LV
E
L_IN
L_OUT
B_UP
B_DN
R40
FS7
D9
FS10
FS9
FS5
FS4
FS3
FS6
U9
R3
D19
D18
D21
D20
D16
D17
D15
D14
RL1
RL2
RL3
RL4
NUVL
CONTROLLER REV
-3.1-1
The Braun Corporation
PWR-IN
1802
1002
R43
R41
U22
102
R38
FS1
1
OH
IN
GND
12V
-B
LIGHT
ALARM
CONTRAST
OBAR S 1
W
All basic functions (UP,
DOWN, STOW and
DOOR) should show a
value of 1 when activated
via a controlled input
(Hand-held Pendant,
Magnetic, Remote Entry
or 3rd Station Controls).
STOW
DOWN
UP
DOOR
LCD Diagnostic Codes
To change the LCD display from cycle count to diagnostic
mode, press the “diag” button on the control board (see
illustration at right). When finished, press button again to
return to cycle count mode. When all of the harnesses
are correctly connected to the control board, the values
shown in the chart below will display when the correspond-
ing action is taken. “1” will appear to the right of the switch
or sensor name on the LCD module when activated as
shown. If any other value appears on the LCD screen
during the specific diagnostic procedure, verify that the
correct harness is properly connected to both the control
board and the associated lift harness. Repeat the harness
diagnostic procedure. If an incorrect value is still present
after checking the harness and connections, contact The
Braun Corporation Product Support Department.
Hand-held Pendant
diag Button
V104
102
102
102
D7
D8
D5
D6
D3
D4
D
2
R31
cycle
C6
C
OBAR S 1
W
NUVL Control Board
LCD Display
Moving Out
Of Cassette
Moving Up
From Stow
At Floor
Level
Moving Down
From Stow
Ground
Level
Ground Level
OB Out
STLV SW
1
1
LOUT SW
1
FOUT SW
1
1
1
1
1
FLV
SW
1
OBAR SW
1
1
1
1
1
1
MAT
SW
= 1 when mat is activated.
DO
SW
= 1 when door is full open or pin 3 and pin 4 are jumpered.
*IBAR SW
= 1 when inboard locator is activated
Stowed
*(NUVL855C only)