FUNCTION

POSSIBLE CAUSE

REMEDY

4.11 Outer Barrier switch is not

activated or defective.

4.12 Full Out switch is not acti-

vated or defective.

4.13 Hand-held pendant not work-

ing properly.

4.00

LIFT WILL

GO UP WITH

OVERRIDE

SWITCH BUT

NOT WITH

HAND-HELD

PENDANT

Check diagnostic LCD for Outer Barrier switch sta-
tus. Barrier is down or barrier release pin partially
out. See Outer Barrier Occupied Calibration on
page 5. Replace switch as necessary.

Check diagnostic LCD for Full Out switch status.
Adjust or replace switch as necessary.

Check for hand-held pendant illumination and
continuity of the switches. Verify Door Open switch
is functioning correctly.

5.11 Hydraulic down valve bad

5.12 Dirty down valve (clogged)

5.00

LIFT WILL

NOT GO

DOWN WITH

MANUAL

OVERRIDE

OR WITH

HAND-HELD

PENDANT OR

GOES DOWN

SLOWLY

OR DRIFTS

DOWN BY

ITSELF

Check for power on red wire from P.C. board to
Down solenoid when pushing override button or
hand-held pendant button. Replace if necessary.

Flush valve by operating Up & Down manual
override buttons at same time for 4 to 5 seconds
several times.

Troubleshooting Diagnosis Chart

6.00

LIFT WILL GO

DOWN WITH

OVERRIDE

BUT NOT WITH

HAND-HELD

PENDANT

6.11 Full Out switch out of adjust-

ment or defective.

6.12 Door Full Close switch out of

adjustment or defective.

Check diagnostic LCD for Full Out switch status.
Adjust or replace switch as necessary.

Check switch for proper operation/adjustment.
Adjust or replace switch as necessary.

7.00

LIFT WILL NOT

GO OUT WITH

HAND-HELD

PENDANT

7.11 Missing shunt

7.12 Door Open switch out of adjust-
ment or defective

Verify shunt (jumper) is located in the Door Opera-
tor 4-conductor jack (jumper pins 3 & 4) on the
control board when door operators are not used.

Check switch for proper operation/adjustment.
Adjust or replace switch as necessary.

9.00

LIFT WILL NOT

STOW WITH

HAND-HELD

PENDANT

9.11 Stow switch out of adjustment

or defective.

9.12 Platform is occupied or out of
calibration.

Check diagnostic LCD for Stow switch status.
Adjust or replace as necessary.

Remove weight from platform. See Platform
Sense Calibration on page 5.

8.00

LIFT WILL NOT

GO OUT WITH
OVERRIDE OR

HAND-HELD

PENDANT

8.11 Poor plug connections

8.12 Bad in/out motor

8.13 Bad power and ground

Check harness connections A1, A2, B1 and B2

Check power at motor. Replace motor if necessary.

See 1.00