beautypg.com

Operating instructions safety system ces-az-aes, Actuator ces-a-bmb, Dimension drawing – EUCHNER CES-AZ-AES-xxx (Unicode) User Manual

Page 46: Technical data

background image

Operating Instructions Safety System CES-AZ-AES-...

46

Actuator CES-A-BMB

Ì

Cylindrical design M12 x 75

Ì

In combination with read head CES-A-LMN-SC
(with read head CES-A-LNA.../LCA... operating distance on request)

Dimension drawing

Notes

Ì

The actuator can be screwed into the M12 x 0.75 thread provided with the aid
of an insertion tool (Order No. 037 662).

Ì

Flush installation of the actuator in steel is allowed.

Technical Data

Parameter

Value

Unit

min.

typ.

max.

Housing material

Stainless steel

Dimensions

M12 x 0.75, depth 6

mm

Weight

0.002

kg

Ambient temperature

-25

-

+70

°C

Degree of protection

IP67

Installation position

Active face opposite read head

Power supply

Inductive via read head

11

0,80

6

M

12x0,75

Active face