Read head ces-a-lca, Dimension drawing, Typical operating distance – EUCHNER CES-A-UEA-04B (Multicode) User Manual
Page 29: Cube-shaped design 42 x 25 mm
Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B
29
Read head CES-A-LCA...
Ì
Cube-shaped design 42 x 25 mm
Ì
Plastic PE-HD housing material, suitable for use in aggressive media (e.g. ac-
ids, alkalis)
Dimension drawing
Note
The flat seal provided must be used during assembly.
Typical operating distance
With evaluation unit CES-A-UEA-01 and actuator CES-A-BCA
Note
For a side approach direction for the actuator and read head, a minimum distance
of s = 3 mm must be maintained so that the operating distance of the side lobes
is not entered.
Approval
32
42
48
25
31
l
12
14
4,6
8
4,
5
± 0,1
Active face
Active face
2 safety screws M4 x 14
are supplied
Flat seal
Side
lobe
N
-10
-15
-5
0
Centre offset m [mm]
Distance s [mm]
OFF
ON
Switch-on
distance
ON
OFF
Hysteresis
Distance s
S
ao
Output state
Switch-off
distance
OFF
Hysteresis
-20
5
20
15
10
5
10
15
20
Side
lobe
N
Actuator
Read head
s
m