beautypg.com

Read head ces-a-lca, Dimension drawing, Typical operating distance – EUCHNER CES-A-UEA-04B (Multicode) User Manual

Page 29: Cube-shaped design 42 x 25 mm

background image

Operating Instructions Safety System CES-A-UEA-02B/CES-A-UEA-04B

29

Read head CES-A-LCA...

Ì

Cube-shaped design 42 x 25 mm

Ì

Plastic PE-HD housing material, suitable for use in aggressive media (e.g. ac-
ids, alkalis)

Dimension drawing

Note

The flat seal provided must be used during assembly.

Typical operating distance

With evaluation unit CES-A-UEA-01 and actuator CES-A-BCA

Note

For a side approach direction for the actuator and read head, a minimum distance
of s = 3 mm must be maintained so that the operating distance of the side lobes
is not entered.

Approval

32

42

48

25

31

l

12

14

4,6

…

8

…

4,

5

± 0,1

Active face

Active face

2 safety screws M4 x 14
are supplied

Flat seal

Side
lobe

N

-10

-15

-5

0

Centre offset m [mm]

Distance s [mm]

OFF

ON

Switch-on
distance

ON

OFF

Hysteresis

Distance s

S

ao

Output state

Switch-off
distance

OFF

Hysteresis

-20

5

20

15

10

5

10

15

20

Side
lobe

N

Actuator

Read head

s

m